Skip to Main Content
PTAGIS logo link back to home page

Interrogation Site Metadata

SC2 - Lower SF Clearwater R at rkm 2

Status:   Active - Operational
Site Type: Instream Remote Detection System  |  Organization: Biomark
General Operational Period: Year Round
Start Date: 9/19/2011 12:00 AM

Instream detection system consisting of a tandem array located in the lower South Fork Clearwater River. The array (SC2) located at river km 2 (N 46.12749 W -115.97730) consists of a single array of six 20 ft Biomark flat panel antennas each. The array spans approximately 80% of the channel during low flow conditions. SC2 is operated by the Integrated Status and Effectiveness Monitoring Project (ISEMP) cooperators Nez Perce Tribe and Biomark and was installed for continuous monitoring on September 19, 2011. The array includes ISEMP standard site monitoring equipment including: air and water temperature probes, and a water pressure transducer to monitor stream level. Electrical power is provided by grid power and remote communication provided by a cellular modem.

Current Operations

Last File Loaded: SC2-2024-330-P-004.json
Date Last File Loaded: 11/25/2024 5:22 PM
Date Last File Opened: 11/25/2024 1:30 PM
Date Last File Closed: 11/25/2024 4:30 PM
Last Observation Tag: 3DD.0078E1A449
Last Observation Date: 11/25/2024 4:20 AM
Detection Summary: Last Day's Observations
Contacts

Primary Contact:

Cameron Albee
camerona@nezperce.org
541-432-2503

Data Steward:

Kevin Peterson
kevin.peterson@merck.com
208-484-0446
Location
Coordinates: 46.127209, -115.977760  |  River Km: 522.224.120.002
Operational History

Operational history describes the period the site was interrogating for PIT tags. The comments provide anecdotal information about the operation of the site during this period. Site operational periods are updated typically at the end of the calendar year.

Configuration

Configuration metadata includes details about the equipment used at the site to detect and record PIT tags. A new configuration sequence record is created when equipment is added or removed from the site and the period of time it was active. A configuration sequence without an End Date is currently active.

Select Configuration Number:
Start Date:  9/19/2011
End Date:  ----

Site Configuration Diagrams:

Equipment History

Select a type to view the history of equipment installed at this site. A missing End Date implies the information about the equipment is current.

Select Equipment Type:
Photos
Event Log Summary
Archived Event Logs