Interrogation Site Metadata
ANT - Antoine Creek Instream Array
Status: Active - OperationalGeneral Operational Period: Year Round
Start Date: 1/1/2011 12:00 AM
Antoine Creek enters the Okanogan River at RKM 98.5, approximately 6 km upstream from the city of Tonasket, WA. Site ANT is located on Antoine Creek, 0.48 km upstream from the confluence with the Okanogan River. The site consists of 3 pass-through HDPE antennas accompanied by individual IS-1001 reader boards in series. Antenna sizes are as follows (upstream to downstream): Ant1 6 feet, Ant2 6 feet, Ant3 10 feet. The site is on grid power. Two banks of 12volt batteries in series create 24volts to run the MTS-MC unit. The batteries are connected to a timer switcher that will switch battery banks every four hours. The battery bank not running the MTS unit is then charged to capacity using a three-stage battery charger. A bioprobe collects and stores both air and water temperatures as well as the water depth data. The ANT site has a Cloudgate 4G cellular modem which transmits data to PTAGIS and Biologic.
Current Operations
Last File Loaded: | ANT-2024-088-P-002.json |
Date Last File Loaded: | 3/28/2024 9:10 AM |
Date Last File Opened: | 3/28/2024 4:23 AM |
Date Last File Closed: | 3/28/2024 7:23 AM |
Last Observation Tag: | 3DD.003D547B9E |
Last Observation Date: | 3/28/2024 12:19 AM |
Detection Summary: | Last Day's Observations |
Contacts
Location
Operational History
Operational history describes the period the site was interrogating for PIT tags. The comments provide anecdotal information about the operation of the site during this period. Site operational periods are updated typically at the end of the calendar year.
Year | Start Date | End Date | Comments |
---|---|---|---|
2024 | |||
2023 | 1/1/2023 12:00 AM | 1/1/2024 12:00 AM | Start and end dates based on timer tags. |
2022 | 1/1/2022 12:00 AM | 1/1/2023 12:00 AM | Start and end dates based on timer tags. |
2021 | 1/1/2021 12:00 AM | 1/1/2022 12:00 AM | Start and end dates based on timer tags. |
2020 | 1/1/2020 12:00 AM | 1/1/2021 12:00 AM | Start and end dates based on timer tags. See event logs for additional operational information. |
2019 | 1/1/2019 12:00 AM | 12/31/2019 12:00 AM | Start and end dates based on timer tags. |
2018 | 1/1/2018 12:00 AM | 1/1/2019 12:00 AM | |
2017 | 1/1/2017 12:00 AM | 1/1/2018 12:00 AM | |
2016 | 1/1/2016 12:00 AM | 1/1/2017 12:00 AM | |
2015 | 1/1/2015 12:00 AM | 1/1/2016 12:00 AM | |
2014 | 1/1/2014 12:00 AM | 1/1/2015 12:00 AM | |
2013 | 1/1/2013 12:00 AM | 1/1/2014 12:00 AM | |
2012 | 1/1/2012 12:00 AM | 1/1/2013 12:00 AM | |
2011 | 1/1/2011 12:00 AM | 1/1/2012 12:00 AM | Collecting data since November 2009, but just added to PTAGIS this year. |
Configuration
Configuration metadata includes details about the equipment used at the site to detect and record PIT tags. A new configuration sequence record is created when equipment is added or removed from the site and the period of time it was active. A configuration sequence without an End Date is currently active.
Antenna Group | Transceiver ID | Antenna ID |
---|---|---|
Upstream Antenna | 10 | 11 |
Middle Antenna | 10 | 12 |
Downstream Antenna | 10 | 13 |
Site Configuration Diagrams:
Equipment History
Select a type to view the history of equipment installed at this site. A missing End Date implies the information about the equipment is current.
Equipment Code | Description | Start Date | End Date |
---|
Photos
Event Log Summary
This displays the last 25 events, to see the full history, log in to the Event Logs.
Event Date | Event Type | Comments |
---|---|---|
12/6/2021 11:00:00 AM | General |
Node 2 lost current on 12/5 @ 0900. Manually tuned node and current came back on 12/6 @ 1100. |
11/18/2019 10:30:00 AM | SiteUp | Replaced the damaged canbus and site is now operational. |
11/16/2019 8:00:00 PM | SiteDown | Rodent chewed canbus cable between pods 2 and 3, shorted the MTS. |
11/5/2019 10:00:00 AM | SiteUp | MC reinstalled and temporary antenna removed. |
10/7/2019 10:30:00 AM | SiteDown | MC removed for emergency placement at a higher priority site. A single, temporary IS-1001 reader board and 10' antenna was placed at Antenna 3 location for data continuity. |
8/26/2019 1:40:00 PM | General | Upgraded from a MUX to an IS-1001 MTS-MC and installed 3 new IS-1001 reader boards. Removed the 4 old PVC antennas, drove new T-posts and replaced with 3 new HDPE antennas in pass-through orientation. Swapped out old 12V batteries for new ones |
8/13/2019 11:52:00 AM | SiteUp | MUX discovered in Standby mode, placed back to Scan. No tags read since 8/6/2019. |
8/6/2019 11:52:00 AM | SiteDown | MUX went to Standby Mode. |
4/25/2015 5:00:00 AM | General | Unknown data gap 4/25/15-4/27/15. |
4/20/2015 5:00:00 AM | General | Unknown data gap 4/20/15-4/22/15. |
8/25/2014 2:00:00 PM | General | Noise levels down ~15% at all antennas. No sprinklers in orchard? |
7/30/2014 9:00:00 AM | General | Increased noise level ~50%. Unplug and re-tune all antennas. Switch to multiple ground types. No change in noise. Disconnect grounds, re-tune. |
7/23/2014 11:00:00 AM | General | Disconnect ground from terminal strip. Noise reduced. Watch overtime. |
7/10/2014 9:00:00 AM | General | Re-tune antennas to reduce noise issues. Watch overtime. |
5/27/2014 10:00:00 AM | General | Antenna 4 high noise. Possible ghost tag. Re-tune all antennas and monitor overtime. |
4/9/2014 11:00:00 AM | General | Tune all antennas. Increased noise issues. Watch overtime. |
4/7/2014 12:00:00 PM | General | Tune all antennas. Noise down ~20%. |
3/11/2014 12:00:00 PM | General | Continued high noise. Re-tune all antennas. Ground stake to negative terminal only. Watch overtime. |
2/26/2014 1:00:00 PM | General | Continued noise issues ~30-60%. Connect MUX cable to negative terminal strip. Remove housing to negative terminal strip. Remove MUX housing to jobox to ground stake. |
2/25/2014 1:00:00 PM | General | Continued high noise ~70-80%. Undo power cord ground to jobox. Grounding only MUX housing to negative terminal strip. |
2/24/2014 12:00:00 PM | General | Continued high noise. Download CR1000. Ground MUX housing to negative terminal strip. Leave MUX cable to box ground. |
2/18/2014 10:00:00 AM | General | Download CR1000 and replace MUX power cord. Ground to jobox, re-tune and watch overtime. Quick reset modem. |
1/10/2014 4:00:00 PM | General | File gap possibly due to high noise during this time period. |
1/9/2014 2:00:00 PM | General | Continued high noise. Disconnect ground, cycle MUX and reset parameters. Following re-tune, noise ~30-40%. |
1/8/2014 11:00:00 AM | General | High noise ~70-80%. Re-connect ground (MUX to box to ground rod). Re-tune and watch overtime. |