Skip to Main Content
PTAGIS logo link back to home page

Interrogation Site Metadata

UMC - Upper Manastash Creek

Status:   Active - Operations Unspecified
Site Type: Instream Remote Detection System  |  Organization: Yakama Nation
General Operational Period: Year Round
Start Date: 4/10/2017 12:00 AM

The Upper Manastash in-stream pit tag array is located at 46.967935, -120.683865, just below the county bridge near the mouth of Manastash canyon. The site has two 20 ft X 24 in Biomark lite flat plate antennas both spanning the wetted width of the creek. The antennas are anchored to the substrate with MR-4 anchors. Each antenna has an IS1001 in a Biomark submersible enclosure. The enclosures are daisy-chained with 1 cable running 100 ft to the enclosure holding the IS1001 MTS. The site is hooked up to grid power and was installed by Yakama Nation and WDFW.

Current Operations

Last File Loaded: UMC-2022-276-P-001.json
Date Last File Loaded: 4/17/2023 12:50 PM
Date Last File Opened: 10/3/2022 8:35 AM
Date Last File Closed: 11/29/2022 12:10 PM
Last Observation Tag: 3DD.003D73B097
Last Observation Date: 4/12/2023 5:40 PM
Detection Summary: Last Day's Observations

Contacts

Primary Contact:

Gabriel Temple
gabriel.temple@dfw.wa.gov
509-933-6080

Data Steward:

Zack Mays
zack_mays@yakama.com

Location

Coordinates: 46.967935, -120.683865  |  River Km: 539.253.010

Operational History

Operational history describes the period the site was interrogating for PIT tags. The comments provide anecdotal information about the operation of the site during this period. Site operational periods are updated typically at the end of the calendar year.

Year Start Date End Date Comments
2024
2023 1/1/2023 12:00 AM 4/13/2023 12:00 AM Start and end dates based on timer tags.
2022 1/1/2022 12:00 AM 11/30/2022 12:00 AM Start and end dates based on timer tags.
2021 1/12/2021 12:00 AM 9/2/2021 12:00 AM Start and end dates based on timer tags.
2020 1/1/2020 12:00 AM 6/23/2020 12:00 AM Start and end dates based on timer tags. See event logs for additional operational information.
2019 1/1/2019 12:00 AM 12/31/2019 12:00 AM Start and end dates based on timer tags.
2018 1/1/2018 12:00 AM 1/1/2019 12:00 AM Start and end dates based on timer tags.
2017 4/10/2017 12:00 AM 1/1/2018 12:00 AM Start and end dates based on timer tags.

Configuration

Configuration metadata includes details about the equipment used at the site to detect and record PIT tags. A new configuration sequence record is created when equipment is added or removed from the site and the period of time it was active. A configuration sequence without an End Date is currently active.

Select Configuration Number:
Start Date:  3/9/2017
End Date:  ----

Site Configuration Diagrams:

Equipment History

Select a type to view the history of equipment installed at this site. A missing End Date implies the information about the equipment is current.

Select Equipment Type:
Equipment Code Description Start Date End Date

No Photos

Event Log Summary

Event Date Event Type Comments
11/6/2018 8:42:10 AM General on 5-21-2018 at 10:30, antenna 02 was disconnected due to damaged CAN bus cabling. The site was shut down shortly after until repairs could be made.
11/6/2018 8:42:10 AM General on 11-5-2018 at 13:47:38 UMC began collecting data again. Antennas 01 and 02 were replaced with 4", 20' HDPE flat plates. Batteries, IS1001 ACNs, enclosures and CAN bus cables all replaced.
3/21/2017 3:00:00 PM General on 3-21-2017 @ around 15:00, the IS1001 ACN for antenna 01 was damaged and stopped supplying power to the antenna. Antenna 02 was still operational.
3/9/2017 11:26:00 AM General On 3/9/17 at 11:26 AM, UMC became operational.

No Archived Event Logs