Skip to Main Content
PTAGIS logo link back to home page

Interrogation Site Metadata

SW2 - Upper Selway River Array

Status:   Active - Operational
Site Type: Instream Remote Detection System  |  Organization: Nez Perce Tribe
General Operational Period: Year Round
Start Date: 9/11/2017 12:00 AM

Site consists of a pair of Biomark IS1001-Master Controllers, 18-IS1001 readers, sixten 20 ft antennas and two 10 ft antennas. The antennas are arranged in single 340 ft array. IS1001-MC A0 controls antennas 01-09 (from left-bank) and IS1001-MC BO controls antennas 01-09 (from middle of channel to right bank). Site has AC power with Biomark PLC battery switcher, satellite communication and Campbell Scientific CS451 and 109 environmental probes.

Current Operations

Last File Loaded: SW2-2024-356-P-007.json
Date Last File Loaded: 12/21/2024 10:41 PM
Date Last File Opened: 12/21/2024 7:49 PM
Date Last File Closed: 12/21/2024 9:49 PM
Last Observation Tag: 3DD.003D7E4480
Last Observation Date: 11/25/2024 8:14 PM
Detection Summary: Last Day's Observations
Contacts

Primary Contact:

Cameron Albee
camerona@nezperce.org
541-432-2503

Data Steward:

Jason Vogel
jasonv@nezperce.org
208-843-7145
Location
Coordinates: 46.085934, -115.515533  |  River Km: 522.224.120.037.013
Operational History

Operational history describes the period the site was interrogating for PIT tags. The comments provide anecdotal information about the operation of the site during this period. Site operational periods are updated typically at the end of the calendar year.

Configuration

Configuration metadata includes details about the equipment used at the site to detect and record PIT tags. A new configuration sequence record is created when equipment is added or removed from the site and the period of time it was active. A configuration sequence without an End Date is currently active.

Select Configuration Number:
Start Date:  9/11/2017
End Date:  ----

Site Configuration Diagrams:

Equipment History

Select a type to view the history of equipment installed at this site. A missing End Date implies the information about the equipment is current.

Select Equipment Type:
Photos Not Found
Event Log Summary

No Archived Event Logs